Sat Liquid (Press) Sat Liquid (Temp) Subcool Liquid Sat Vapor (Press) Sat Vapor (Temp) Superheated Vapor Wet Steam (Press,X) Wet Steam (P,Enth)
Drybulb, Wetbulb Drybulb, RH Psychrometric Chart
Liquid Leak Vapor Leak Cont Depress (Area) Cont Depress (DP)
CCW LOCA RHR CT SFP Letdown Regenerative TPCW Diesel Jacket Water Build your own U-Tube
Liquid Pressure Drop
Gas Pressure Drop
Alternate Core Cooling

Vapor Blowdown Through a Known Flow Area

Applicable to pipe breaks, tank ruptures,tube ruptures, valve leaks etc.
Upstream Pressure (psia):
Downstream Pressure (psia):
Vapor Quality:
*Flow Area (sqft):
*Diameter (in):
* Enter only one value.
**Critical Pressure Ratio:
**Critical Mass Flux:


Critical Mass Flux Help




The flow is Choked
** If the Quality is less than 1.0, the Critical Pressure
Ratio and the Critical Mass Flux must be entered
Worksheet A and B
Pressure Ratio:0.013
Mass Flux:1816.8lbm/sec/sqft
Mass Flow Rate:2521.6573lbm/sec
Volumetric Flow Rate STP:    18155.9328gpm

Upstream Conditions
Specific Volume:0.40058cuft/lbm
Enthalpy:1189.06BTU/lbm
Temperature:    556.28Deg F
Entropy:    1.38BTU/lbm/F

Downstream Conditions Not Available